Hemodilution Decreases Critical Closing Pressure But Does Not Increase The Aortic To Distal Pressure Gradient In Dogs
J Urzúa, G Núñez, G Meneses, G Lema, R Canessa, C Sacco, J Medel, C Sáez
Keywords
anesthesia, anesthesiology, critical care medicine, education, electronic publication, intensive care medicine, internet, multimedia, online, peer-review, regional anesthesia, trauma
Citation
J Urzúa, G Núñez, G Meneses, G Lema, R Canessa, C Sacco, J Medel, C Sáez. Hemodilution Decreases Critical Closing Pressure But Does Not Increase The Aortic To Distal Pressure Gradient In Dogs. The Internet Journal of Anesthesiology. 1998 Volume 3 Number 3.
Abstract
This work was financed by grant 1940584 from the National Research Fund (FONDECYT)
INTRODUCTION
Hemodilution is used routinely during cardiac surgery and CPB. Its clinical and hemodynamic effects are well documented (1); however, its effect on the arterial zero-flow («critical closing») pressure has not been established. Further, it has been proposed (2) that hemodilution may be responsible for the aortic-to-distal arterial pressure gradient often seen after cardiopulmonary bypass. Aortic and radial arterial pressure waveforms have different waveforms. Normally, systolic pressure is higher in the radial artery than in the aorta; however, mean and diastolic pressures are similar. Resistance changes produced by vasodilators, by occlusion of the radial artery, or by thermoregulation, alter the aortic-to-distal pressure difference. Hemodilution decreases blood viscosity and thus resistance; therefore, the aortic-to-distal pressure difference may be altered as well.
METHODS
Animal handling and upkeep complied with institutional norms. Eleven mongrel dogs weighting 16.6±4.4 Kg were anesthetized with 35 mg/Kg of pentobarbital and 2 mcg/Kg of sufentanyl and mechanically ventilated with oxygen and air. Arterial blood gases and tympanic temperature were controlled. Millar catheter-tipped pressure transducers were located in the ascending aorta and in a distal femoral artery. A snare and an electromagnetic flowmeter were placed around the ascending aorta.
Zero-flow pressure was measured by extrapolation of the arterial pressure decay obtained during a 4-second proximal aortic occlusion. Hemodilution was achieved removing 30 ml/Kg of blood over 5 to 10 minutes and replacing it with warm 0.9% NaCl as required to maintain constant systolic aortic pressure. Hematocrit decreased from 39 ± 11.2 % to 25.6 ± 4.95 %. The effects of 1 mcg/Kg phenyleprine and 4 mcg/Kg nitroprusside were recorded both before and after hemodilution. Effective downstream pressure was measured by extrapolation of the exponential pressure decay during occlusion of the aortic snare, before and after dilution. Statistics. Each dog was its own control. Paired student’s «t» test and repeated- measurements analysis of variance were used. Significance was P=0.05. Results are mean ± SD.
RESULTS
Hemodilution decreased zero-flow pressure, from 44±9 to 36±7mmHg (p<0.05) in the aorta, and from 51±2 to 37±3.1mmHg (p<0.05) in the distal femoral artery. As expected, hemodilution increased cardiac output from 78±25 to 142±57 ml/min/Kg (p<0.05) and decreased vascular resistance from 1.3±0.5 to 0.8±0.4 {mmHg/ml/min}Kg, (p<0.05). Diastolic aortic pressure decreased from 86±17 to 79±15mmHg (p<0.05), but systolic and mean pressures were unchanged (from 108±20 to 104±21mmHg and from 97±20 to 93±17mmHg, respectively). Peak systolic femoral pressure was 13.5±7.2mmHg higher than aortic before, and 17.5± 8.7mmHg after, hemodilution (p>0.1). Mean arterial pressure in the aorta was not significantly different from the distal femoral artery, both before (97±20 vs. 95±19mmHg, respectively) and after hemodilution (93±17 vs. 91±17mmHg, respectively).
Figure 2
Figure 3
Figure 4
Figure 5
DISCUSSION
Hemodilution decreased significantly the zero-flow pressure. Causes underlying zero-flow pressure are not completely known. It is generally assumed that it results from microvascular collapse, due to vasoconstriction or higher surrounding pressure. However, the fact that hemodilution decreased zero-flow pressure suggests that physical characteristics of the blood, such as viscosity, are at least in part responsible. Contrary to our hypothesis, acute normovolemic hemodilution had no significant effect on the aortic-to-distal arterial pressure difference.
Unlike resistance decreases due to vasodilators or thermoregulation, resistance decrease due to hemodilution did not alter the normal difference between aortic and femoral systolic pressure. Similarly, the pressure waveforms were not affected. This was against our hypothesis and we have no firm explanation for this negative result.
The arterial pressure waveform is a very complex phenomenon. Differences in shape and peak systolic value between aortic and distal pressures depend on many factors, related to ventricular ejection and to the physics of the arterial tree. Ventricular factors include contractility, dP/dt and Vmax, pre- and afterload, pressure, stroke volume and velocity of ejection. Arterial factors include wall tension, wave propagation, characteristic frequencies, wall compliances, inertial effects, peripheral resistance, and pressure itself. We hypothesized that blood viscosity was one of the variables involved; unfortunately this was not the case.
The meaning of the arterial “critical closing pressure” is debatable. It has been attributed to dynamic compliance effects, to vascular collapse, to perivascular pressure, and to the particular rheological characteristics of blood. The fact that it decreased when viscosity decreased with hemodilution may suggest that rheological factors are possibly important.