Advertisement
Advertisement

The Internet Journal of Anesthesiology ISSN: 1092-406X


Treatment: Case Study in Cardiovascular Anesthesiology/Surgery


O. Wenker Baylor College of Medicine
H. Doerr Baylor College of Medicine
H. Safi Baylor College of Medicine
A. Alvarado Baylor College of Medicine
M. Weiner Baylor College of Medicine

Citation:  O. Wenker, H. Doerr, H. Safi, A. Alvarado & M. Weiner: Treatment: Case Study in Cardiovascular Anesthesiology/Surgery. The Internet Journal of Anesthesiology. 1998 Volume 2 Number 1

Keywords:  anesthesiology, anesthesia, intensive care medicine, critical care medicine, trauma, regional anesthesia, education, multimedia, internet, online, electronic publication, peer-review

Abstract


Surgery

The patient was scheduled for ascending aortic aneurysm repair. The patient was induced with high dose fentanyl, midazolam, and relaxed with pavulon. Isoflurane was the inhaled anesthetic of choice. The surgical procedure entailed evaluation of the aortic valve and the ascending portion of aorta.

The following pictures were taken during surgery.


                  Clamping of the ascending aorta prior resection of the ascending aneurysm

Clamping of the ascending aorta prior resection of the ascending aneurysm


                  Ascending aorta clamped

Ascending aorta clamped

After repair of the ascending aorta the patient developed a severe coagulopathy. Appropriate volume replacement was achieved but preexisting cardiac and renal insufficiency, a poor response to diuretics, and high volume requirements lead to heart failure that was not responsive to maximum inotropic support. An intraaortic ballon pump could not be inserted because of the thoracoabdominal aortic aneurysm. The decision was taken by the surgeon to incorporate biventricular support devices after which the surgery was concluded. The patient was then transferred to the cardiovascular ICU. The patient did not recover and died a few days later.

Preoperative transesophageal echocardiography and preoperative CT scans did not confirm the primary diagnosis of an aortic valve leak but revieled an aneurysm starting at the sinus valsava of the aortic valve extending to the femoral arteries. Changes in geometry at the level of the aortic and mitral valve resulted in a secondary mitral insufficiency. Preexisting morbidity (cardiac, renal, pulmonary) contributed to the high risk involved in the repair of the ascending aneurysm.


Generated at: Thu, 09 Feb 2012 13:13:40 -0600 (00001b7e) — http://www.ispub.com:80/journal/the-internet-journal-of-anesthesiology/volume-2-number-1/treatment-case-study-in-cardiovascular-anesthesiology-surgery.html