The Internet Journal of Anesthesiology™ ISSN: 1092-406X

| Home | Editors | Current Issue | Archives | Instructions for Authors | Disclaimer | Bookmark and Share Share with others |
 

Anesthesia for the Surgery of Intracranial Aneurysms

O. Wenker
Physical Address

H. Doerr
Physical Address

H. Safi
Physical Address

A. Alvarado
Physical Address

M. Weiner
Physical Address

Citation: O. Wenker, H. Doerr, H. Safi, A. Alvarado & M. Weiner : Anesthesia for the Surgery of Intracranial Aneurysms . The Internet Journal of Anesthesiology. 1998 Volume 2 Number 1


Keywords: anesthesiology | anesthesia | intensive care medicine | critical care medicine | trauma | regional anesthesia | education | multimedia | internet | online | electronic publication | peer-review

 


Results - Radiology Findings

Thumbnail: Chest X-ray: Cardiomegaly .
Chest X-ray: Cardiomegaly .

Thumbnail: CT scan chest ap:Aneurysm of the ascending and transverse aorta. Wide aortic valve area
CT scan chest ap:Aneurysm of the ascending and transverse aorta. Wide aortic valve area

Thumbnail: CT scan chest lateral:Aneurysm of the ascending, transverse and thoracoabdominal aorta. Wide aortic valve area.
CT scan chest lateral:Aneurysm of the ascending, transverse and thoracoabdominal aorta. Wide aortic valve area.

Thumbnail: CT scan abdomen: Abdominal aortic aneurysm with actual perfused area (white) and clots or false lumen (gray).
CT scan abdomen: Abdominal aortic aneurysm with actual perfused area (white) and clots or false lumen (gray).

Transesophageal Echography Findings

Thumbnail: TEE 5 chamber view: Chamber sizes appear normal. Tricuspid leaflets appear normal. Anterior mitral leaflet is being pulled ante...
TEE 5 chamber view: Chamber sizes appear normal. Tricuspid leaflets appear normal. Anterior mitral leaflet is being pulled anteriorly and septaly. There is a pseudoaneurysm present at the sinus of valsava level surrounding a prosthetic aortic valve.

Thumbnail: TEE 5 chamber view: Demonstrating the separation between the prosthetic aortic valve and the aortic annulus/sinus valsava.
TEE 5 chamber view: Demonstrating the separation between the prosthetic aortic valve and the aortic annulus/sinus valsava.

Thumbnail: TEE 4 chamber view: Color doppler flow demonstrates severe excentric mitral regurgitation secondary to changes in anterior mitr...
TEE 4 chamber view: Color doppler flow demonstrates severe excentric mitral regurgitation secondary to changes in anterior mitral leaflet geometry.

Diagnosis

Ascending aortic aneurysm with mitral insufficiency. Aneurysm of the transverse arch and thoracoabdominal aorta.

What would be your treatment? Click [here] for an answer.


This article was last modified on Fri, 13 Feb 09 13:11:58 -0600

This page was generated on Sat, 20 Mar 10 06:19:42 -0500, and may be cached.

Advertisement